APC by Schneider Electric- InRow RD ACRD602P

 APC BY SCHNEIDER ELECTRIC PRECISION AIR CONDITIONING UNIT INROW RD ACRD602P  

FEATURES

  • Integrated Humidity Management

  • The ACRD602P incorporates a built-in steam humidifier, ensuring precise humidity control within data centers and server rooms to maintain stable environmental conditions.

  • Predictable Row-Based Cooling Architecture

  • By positioning the cooling unit directly between racks, the system captures hot exhaust air at the source, eliminating airflow mixing and providing predictable cooling performance.

  • Intelligent Environmental Monitoring

  • A microprocessor-based control system actively monitors temperature, airflow, and humidity levels, enabling dynamic adjustments to cooling capacity.

  • Energy-Optimized Variable Fan Operation

  • Variable-speed fans adjust airflow according to heat load demand, reducing energy consumption while maintaining consistent server inlet temperatures.

  • Designed for High-Density Data Centers

  • Engineered for mission-critical facilities, the system supports high-density rack deployments while maintaining efficient thermal management.

SPECIFICATIONS

  • Product Type: In-Row Air-Cooled Precision Cooling Unit with Humidifier

  • Cooling Method: Direct expansion (DX) air-cooled cooling

  • Compressor Type: Scroll compressor

  • Airflow Capacity: Approximately 4000 CFM

  • Humidification Output: Approximately 6.6 lb/hr (3.0 kg/hr)

  • Rack Integration: 42U in-row installation

  • Input Voltage: 380–415 V AC, 3-phase

  • Airflow Pattern: Rear intake with horizontal discharge

  • Operating Temperature: −20°C to 50°C

  • Noise Level: Approximately 84 dBA

 APC BY SCHNEIDER ELECTRIC PRECISION AIR CONDITIONING UNIT INROW RD ACRD200  

FEATURES

  • Compact 300 mm In-Row Cooling Design

  • The ACRD200 is a 300 mm-wide in-row cooling system designed to be installed directly between racks, delivering cooling closer to the heat source and improving thermal efficiency in server rooms and small data centers.

  • Predictable Cooling Architecture

  • By placing the cooling unit within the rack row, the system eliminates air mixing and ensures stable server inlet temperatures, improving overall cooling predictability.

  • Variable-Speed Fan Technology

  • Variable-speed fans dynamically adjust airflow to match heat loads, reducing energy consumption and improving cooling efficiency during off-peak conditions.

  • Advanced Microprocessor Control System

  • A multifunction LCD console provides monitoring, alarm notifications, and control of system parameters for efficient operation and maintenance.

  • Containment System Compatibility

  • The unit can operate with rack containment systems such as hot-aisle or cold-aisle containment, improving cooling efficiency and reducing hot-spot risks.

SPECIFICATIONS

  • Product Type: In-Row Fluid-Cooled Precision Cooling System

  • Cooling Capacity: Up to approximately 10.9 kW

  • Maximum Airflow: 2290 CFM (≈1081 L/s)

  • Compressor Type: Scroll compressor

  • Input Voltage: 208–230 V AC

  • Power Consumption: 4600 W

  • Refrigerant Type: R-410A

  • Air Intake / Discharge: Rear return / horizontal discharge

  • Rack Compatibility: 42U rack installation

  • Dimensions (H × W × D): 1991 × 300 × 1070 mm

  • Weight: Approximately 199 kg (438 lb)

Inquire Now

a man riding a skateboard down the side of a ramp
a man riding a skateboard down the side of a ramp
Address

23 1st Ave. Brgy. Bagong Lipunan ng Crame, Cubao, Quezon City, 1111 Metro Manila, Philippines

Contacts

+632 8287 4114 | +632 8254 1594 +632 7720 1310 | + 632 8726 9129
inquiry@fastlink.ph | helpdesk@fastlink.ph

About Us

Our Solutions

Our Services

Contact Us