Dahua- HY-C102-4

  DAHUA FDAS HY-C102-4  

FEATURES

  • Wide-Range Main Power Supply

  • Compatible with AC 90–240 VAC, ensuring reliable performance.

  • Ethernet & RS‑485 Connectivity

  • Supports network linkage and IoT platform integration.

  • Visual + Audible Alarm Functions

  • Automatically activates sirens/strobes and bell outputs upon detection of fire signals.

  • Built-In Event Recording & Export

  • Logs fire events, faults, and operations for later retrieval and archiving.

  • Four Conventional Zones

  • Each zone accommodates up to 32 detectors, ideal for smaller installations.

SPECIFICATIONS

  • Zones: 4

  • Zone Capacity: 32 detectors per zone

  • Main Power: AC 90–240 V, 50/60 Hz

  • Backup Power: 2 × 12 V / 2.5 Ah batteries

  • Output Current: 2 A

  • Sounder Output: Fault: 50 dB, Alarm: 60 dB

  • Fire Bell Output: DC 28 V / 500 mA

  • Dimensions: 310 × 73 × 227 mm (12.20″ × 2.87″ × 8.94″)

  • Weight: 3.5 kg (5 kg with batteries)

  • Operating Temp: –10 °C to +50 °C

  • Operating Humidity: ≤ 95% RH (non‑condensing)

  • Protection Grade: IP30

  • Installation: Wall mount

  • Standards Compliance: EN54‑2 & EN54‑4 certified

  DAHUA FDAS HY-C132  

FEATURES

  • Intelligent Heat Sensing Algorithm

  • Utilizes differential temperature detection to reliably discern rapid heat changes while minimizing false alarms.

  • Polarity-Free Two-Wire Design

  • Simplifies wiring and increases resilience to polarity errors.

  • Mechanical Stability & EMC Protection

  • Features anti-corrosive terminals, non-loosening screws, and strong electromagnetic interference (EMC) resistance.

  • Wide Environmental Suitability

  • Operates reliably in varied conditions; suitable for ceilings up to 12 m in height.

  • Visual Alarm Indicator

  • Red LED flashes intermittently during polling and stays solid upon alarm.

SPECIFICATIONS

  • Working Voltage: DC 16–28 V

  • Rated Power: 3.408 mW

  • Standby Current: ≤ 120 μA

  • Alarm Current: ≤ 170 μA

  • Coverage (H ≤ 4 m): ≈ 50 m²; (4–12 m): ≈ 30 m²

  • Operating Temp: –10 °C to +50 °C

  • Humidity: ≤ 95% RH (non-condensing)

  • Dimensions: Φ 100 mm × 50 mm

  • Weight: 81 g (with base)

  • Mounting: Ceiling mount

  • Compliance: EN54‑5:2017/A1:2018 standard

  DAHUA FDAS HY-C133  

FEATURES

  • Smart Dual-Photoelectric Sensing

  • Detects smoke accurately using two optical chambers for reduced false positives.

  • Intelligent BLC Algorithm

  • Automatically adjusts alarm thresholds based on chamber contamination, reducing maintenance frequency.

  • Built-in Audible Buzzer

  • Provides both visual and audible alarms directly at the detector.

  • Durable Wiring with Secure Terminals

  • Non-loosening screws and acid-resistant contacts ensure reliability.

  • Polarity-Free Wiring Compatible

  • Supports convenient four-wire, polarity-free loop connection.

SPECIFICATIONS

  • Working Voltage: DC 9 V–28 V

  • Standby Current: ≤ 350 µA

  • Alarm Current: ≤ 100 mA

  • Coverage Area: ≤ 4 m ceiling: 150 m²; 4–12 m: 80 m²

  • Operating Temp: –10 °C to +55 °C (14–131 °F)

  • Humidity: ≤ 95% RH (non‑condensing)

  • Dimensions: 104 × 103.6 × 46 mm (4.09″×4.08″×1.81″)

  • Weight: 122 g (with base)

  • Installation: Ceiling mount

  • Alarm Mode: Visual and audible via built-in buzzer

  • Compliance: EN 54‑7

Inquire Now

a man riding a skateboard down the side of a ramp
a man riding a skateboard down the side of a ramp
Address

23 1st Ave. Brgy. Bagong Lipunan ng Crame, Cubao, Quezon City, 1111 Metro Manila, Philippines

Contacts

+632 8287 4114 | +632 8254 1594 +632 7720 1310 | + 632 8726 9129
inquiry@fastlink.ph | helpdesk@fastlink.ph

About Us

Our Solutions

Our Services

Contact Us