Hochiki- 2 SLC'S WITH NETWORK CARD, WITHOUT COMMUNICATOR LA203J1-10
HOCHIKI FDAS 2 SLC'S NETWORK CARD, WITHOUT COMMUNICATOR LA203J1-10
FEATURES
Includes network interface for panel networking
Enables linked operation and shared logic across fire panels.
Supports same advanced configuration suite as base model
Feature parity with LA203H1‑10 except for added network module.
Large memory and logic capacity
400 subaddress points per loop and 5,000 programmable cause-and-effect rules.
SPECIFICATIONS
SLC loops: 2 (400 mA each)
Power Supply: 10.25 A (auto-voltage sensing)
NACs: 4 Class B or 2 Class A, internally synchronized
Programmable Inputs: 3 (fire/trouble)
Relays: 5 Form C outputs (1 A @ 30 VDC)
Display: 7″ touchscreen; User accounts: up to 64; Soft keys: 24
Device capacity: up to 400 subaddress points per loop
Logic: 5,000 cause & effects, > 50,000 I/O events
Programming: USB PC or memory stick
Network: Optional via external NIC
Mounting: 4-slot standard enclosure
Compliance: UL864, FM pending; expandable modular design
Integrated Network Module (RS‑485/Ethernet for panel networking)
HOCHIKI FDAS 4 SLC'S COMMUNICATOR, NO NETWORK CARD LA203I2-10
FEATURES
Four-loop system with built-in communicator (DACT)
Ideal for mid-size installations requiring remote alarm reporting.
Programmable NAC and synchronized outputs
Supports up to 4 Class B or 2 Class A NACs with built-in syncing.
Full touchscreen UI with cause-and-effect logic
Same interface, logic capability, and expandability as two-loop units.
SPECIFICATIONS
SLC loops: 4 (400 mA each)
Power Supply: 10.25 A
Inputs/Relays: 3 programmable inputs; 5 form‑C relays
Logic capacity: 400 addresses per loop; 5,000 cause‑effect rules
Display/UI: 7″ touchscreen; up to 64 users; 24 soft keys
Communicator: Built-in DACT (Contact ID, SIA)
Programming: USB or memory stick supported
Enclosure: 4‑slot standard plexi‑door or cabinet
Other features as LA203H1‑10.
HOCHIKI FDAS 4 SLC'S WITH NETWORK CARD, WITHOUT COMMUNICATOR LA203J2-10
FEATURES
Four SLC loops for addressable device support
Supports four supervised loops, each capable of up to 400 mA, making it suitable for larger installations.
Built-in network interface card for panel networking
Enables communication between panels over RS‑485 or Ethernet for system-wide monitoring and coordination.
High-current 10.25 A power supply
Supports multiple NACs and auxiliary devices, ensuring reliable notification output.
Advanced user interface with touchscreen control
Includes a 7″ full-color resistive touch display with up to 64 user accounts and 24 programmable soft keys.
Flexible programmable logic and capacity
Allows up to 400 sub‑address points per loop (800 per dual-loop module), up to 5,000 cause-and-effect rules and >50,000 I/O events.
SPECIFICATIONS
Loops (SLC): 4 loops
SLC loop current: 400 mA
NACs: Programmable as 4 Class B or 2 Class A (with internal sync)
Panel power supply rating: 10.25 A
Programmable inputs: 3
Programmable relay outputs: 5
Addressable points per loop: 400 sub‑address points (or 800 per loop module)
Cause & effect programming: Up to 5,000 programmable cause‑and‑effect events; over 50,000 inputs/outputs for system logic.
Inquire Now
Address
23 1st Ave. Brgy. Bagong Lipunan ng Crame, Cubao, Quezon City, 1111 Metro Manila, Philippines
Contacts
+632 8287 4114 | +632 8254 1594 +632 7720 1310 | + 632 8726 9129
inquiry@fastlink.ph | helpdesk@fastlink.ph