Hochiki- SCI-B67 & SCI-B47 Short Circuit Isolator Digital Analog Sensor Bases
HOCHIKI FDAS SCI-B67 & SCI-B47 SHORT CIRCUIT ISOLATOR DIGITAL ANALOG SENSOR BASES
FEATURES
Short Circuit Isolation
Detects short circuit conditions on the loop and isolates the affected section, ensuring the rest of the system remains operational.
Compatibility with Hochiki NS Digital Analog Sensors
Designed for use with Hochiki’s NS Digital Analog sensors, including AIE-EA, ALG-V, ALK-V, ALN-V, ATG-EA, ATJ-EA, ACA-V, ACC-V, ACD-V, and ALO-V.
LED Indication
Features a yellow LED indicator to clearly show the status of the isolator.
Tamper Protection
Equipped with a plastic tamper-lock to prevent unauthorized removal and tampering.
Easy Installation
Utilizes solder-less screw terminals for quick, secure, and reliable wiring connections.
SPECIFICATIONS
Operating voltage: 17-41 V DC
Loop idle current: approximately 160 µA
Maximum active alarm current: up to ~10 mA
Compatible detectors: AIE-EA, ALG-V, ALK-V, ALN-V, ATG-EA, ATJ-EA, ACA-V, ACC-V, ACD-V, ALO-V
Models / Size:
SCI-B47: 4″ mounting base
SCI-B67: 6″ mounting base
Operating temperature range: 0 °C to 38 °C (32 °F to 100 °F) for listed spec version
Storage temperature: -30 °C to +70 °C (-22 °F to 158 °F)
Maximum humidity: up to 93% RH non-condensing
HOCHIKI FDAS DH-100-A ADDRESSABLE DUCT SMOKE DETECTOR
FEATURES
Low Airflow Sensitivity
The DH-100-A is UL 268A listed for low airflow detection, operating effectively at air velocities as low as 100 feet per minute.
Integrated Smoke Detection
Equipped with the ALN-DH Analog Addressable Photoelectric Smoke Detector, it provides early detection of smoke and combustion products in HVAC ducts.
Seamless System Integration
Designed for compatibility with building automation and fire alarm systems, facilitating centralized monitoring and control.
Efficient Installation
Features a rugged gray steel back box with a clear cover, allowing for quick and easy installation without the need for screens or filters to clean.
Remote Monitoring Capability
Offers optional remote LED alarm indication, enabling status monitoring from a distance.
UL Certification
UL 268A listed, ensuring compliance with industry standards for duct smoke detectors.
SPECIFICATIONS
Product Code: DH-100‑A (0200‑10110)
Detection: Analog photoelectric sensor designed for duct installation
Air velocity rating: 100–4000 ft/min
Standby current: ~450 µA; Alarm current: max 30 mA
Ambient range: 32 °F–100 °F (0 °C–38 °C); humidity up to 93% RH non-condensing
Housing: Gray steel backbox with clear cover; size ~9 ⅛″ × 7 ¼″ × 2 ¼″; weight ~3 lbs
Sampling tubes: Supplied with 7.5″ exhaust tube; intake available in 2.5′, 5′, 10′ lengths
Compliance: UL 268A, NFPA 90A, NFPA 72 duct detector listings
Remote LED: Additional terminals for remote alarm LED indicator with up to ~8 mA driver
HOCHIKI FDAS DCP-FRCMA FAST RESPONSE CONTACT MONITORING MODULE
FEATURES
Rapid addressable contact-monitoring solution
The module is specifically designed to monitor dry-contact alarm initiating devices (like pull stations or water-flow switches) and report changes immediately via the DCP (Digital Communications Protocol) on the SLC loop.
Single loop address, high device capacity and configurable contact modes
Each module is individually addressed (stored in onboard EEPROM) and up to 127 devices can be installed on one DCP loop. It supports both Normally Open (NO) and Normally Closed (NC) contact monitoring (in Class B) and also supports wiring in Class A or Class B configurations.
Fault supervision, optional short-circuit isolator (SCI version)
The version ending in “-I” includes built-in SCI functionality: if a short circuit occurs on the S-SC line, the module isolates the fault, lights a yellow LED indicator, and reports the condition to the control panel—ensuring the remainder of the loop remains operational.
SPECIFICATIONS
Product Code: 0400-02200
Supply Voltage: 25.3 ~ 39 VDC
Average Current Consumption: 630 µA (Typical)
Alarm Current Consumption: 6.3 mA
SCI On Resistance: 40 mΩ Max. (Normal Condition)
SCI Fault Detection Threshold: 12 volts (Typical)
SCI Isolation Current (Short Circuit Condition): 10 mA (Typical)
Maximum Quantity Per Loop: 127 devices
Dimensions: 4.2"W x 4.7"H x 1.4"D
Mounting: 4" square electrical box
Ambient Temperature: 32°F (0°C) ~ 120°F (49°C)
Relative Humidity: 90% RH Non-condensing
Wire Gauge: Accepts up to 14 AWG
LED Indicators: Bi-colored (Yellow for short circuit condition)
Power Source: No external 24 VDC power required
UL Listed: Yes
Inquire Now
Address
23 1st Ave. Brgy. Bagong Lipunan ng Crame, Cubao, Quezon City, 1111 Metro Manila, Philippines
Contacts
+632 8287 4114 | +632 8254 1594 +632 7720 1310 | + 632 8726 9129
inquiry@fastlink.ph | helpdesk@fastlink.ph
About Us
Our Solutions
Our Services
Contact Us