Hochiki- SCI-B67 & SCI-B47 Short Circuit Isolator Digital Analog Sensor Bases

  HOCHIKI FDAS SCI-B67 & SCI-B47 SHORT CIRCUIT ISOLATOR DIGITAL ANALOG SENSOR BASES  

FEATURES

  • Short Circuit Isolation

  • Detects short circuit conditions on the loop and isolates the affected section, ensuring the rest of the system remains operational.

  • Compatibility with Hochiki NS Digital Analog Sensors

  • Designed for use with Hochiki’s NS Digital Analog sensors, including AIE-EA, ALG-V, ALK-V, ALN-V, ATG-EA, ATJ-EA, ACA-V, ACC-V, ACD-V, and ALO-V.

  • LED Indication

  • Features a yellow LED indicator to clearly show the status of the isolator.

  • Tamper Protection

  • Equipped with a plastic tamper-lock to prevent unauthorized removal and tampering.

  • Easy Installation

  • Utilizes solder-less screw terminals for quick, secure, and reliable wiring connections.

SPECIFICATIONS

  • Operating voltage: 17-41 V DC

  • Loop idle current: approximately 160 µA

  • Maximum active alarm current: up to ~10 mA

  • Compatible detectors: AIE-EA, ALG-V, ALK-V, ALN-V, ATG-EA, ATJ-EA, ACA-V, ACC-V, ACD-V, ALO-V

  • Models / Size:

  • SCI-B47: 4″ mounting base

  • SCI-B67: 6″ mounting base

  • Operating temperature range: 0 °C to 38 °C (32 °F to 100 °F) for listed spec version

  • Storage temperature: -30 °C to +70 °C (-22 °F to 158 °F)

  • Maximum humidity: up to 93% RH non-condensing

  HOCHIKI FDAS DH-100-A ADDRESSABLE DUCT SMOKE DETECTOR  

FEATURES

  • Low Airflow Sensitivity

  • The DH-100-A is UL 268A listed for low airflow detection, operating effectively at air velocities as low as 100 feet per minute.

  • Integrated Smoke Detection

  • Equipped with the ALN-DH Analog Addressable Photoelectric Smoke Detector, it provides early detection of smoke and combustion products in HVAC ducts.

  • Seamless System Integration

  • Designed for compatibility with building automation and fire alarm systems, facilitating centralized monitoring and control.

  • Efficient Installation

  • Features a rugged gray steel back box with a clear cover, allowing for quick and easy installation without the need for screens or filters to clean.

  • Remote Monitoring Capability

  • Offers optional remote LED alarm indication, enabling status monitoring from a distance.

  • UL Certification

  • UL 268A listed, ensuring compliance with industry standards for duct smoke detectors.

SPECIFICATIONS

  • Product Code: DH-100‑A (0200‑10110)

  • Detection: Analog photoelectric sensor designed for duct installation

  • Air velocity rating: 100–4000 ft/min

  • Standby current: ~450 µA; Alarm current: max 30 mA

  • Ambient range: 32 °F–100 °F (0 °C–38 °C); humidity up to 93% RH non-condensing

  • Housing: Gray steel backbox with clear cover; size ~9 ⅛″ × 7 ¼″ × 2 ¼″; weight ~3 lbs

  • Sampling tubes: Supplied with 7.5″ exhaust tube; intake available in 2.5′, 5′, 10′ lengths

  • Compliance: UL 268A, NFPA 90A, NFPA 72 duct detector listings

  • Remote LED: Additional terminals for remote alarm LED indicator with up to ~8 mA driver

  HOCHIKI FDAS DCP-FRCMA FAST RESPONSE CONTACT MONITORING MODULE  

FEATURES

  • Rapid addressable contact-monitoring solution

  • The module is specifically designed to monitor dry-contact alarm initiating devices (like pull stations or water-flow switches) and report changes immediately via the DCP (Digital Communications Protocol) on the SLC loop.

  • Single loop address, high device capacity and configurable contact modes

  • Each module is individually addressed (stored in onboard EEPROM) and up to 127 devices can be installed on one DCP loop. It supports both Normally Open (NO) and Normally Closed (NC) contact monitoring (in Class B) and also supports wiring in Class A or Class B configurations.

  • Fault supervision, optional short-circuit isolator (SCI version)

  • The version ending in “-I” includes built-in SCI functionality: if a short circuit occurs on the S-SC line, the module isolates the fault, lights a yellow LED indicator, and reports the condition to the control panel—ensuring the remainder of the loop remains operational.

SPECIFICATIONS

  • Product Code: 0400-02200

  • Supply Voltage: 25.3 ~ 39 VDC

  • Average Current Consumption: 630 µA (Typical)

  • Alarm Current Consumption: 6.3 mA

  • SCI On Resistance: 40 mΩ Max. (Normal Condition)

  • SCI Fault Detection Threshold: 12 volts (Typical)

  • SCI Isolation Current (Short Circuit Condition): 10 mA (Typical)

  • Maximum Quantity Per Loop: 127 devices

  • Dimensions: 4.2"W x 4.7"H x 1.4"D

  • Mounting: 4" square electrical box

  • Ambient Temperature: 32°F (0°C) ~ 120°F (49°C)

  • Relative Humidity: 90% RH Non-condensing

  • Wire Gauge: Accepts up to 14 AWG

  • LED Indicators: Bi-colored (Yellow for short circuit condition)

  • Power Source: No external 24 VDC power required

  • UL Listed: Yes

Inquire Now

a man riding a skateboard down the side of a ramp
a man riding a skateboard down the side of a ramp
Address

23 1st Ave. Brgy. Bagong Lipunan ng Crame, Cubao, Quezon City, 1111 Metro Manila, Philippines

Contacts

+632 8287 4114 | +632 8254 1594 +632 7720 1310 | + 632 8726 9129
inquiry@fastlink.ph | helpdesk@fastlink.ph