Hochiki- XT+1R - Multi-Area Addressable Releasing Control Unit, 1 Module, Red

  HOCHIKI FDAS XT+1R - MULTI-AREA ADDRESSABLE RELEASING CONTROL UNIT  

FEATURES

  • Multi-Area Releasing Capability

  • Supports up to two releasing zones in a single panel, providing flexible control for multi-area suppression systems using CO₂, FM-200®, NOVEC™ 1230, or water mist agents.

  • Integrated Power and Battery Backup

  • Features a built-in 5.25A power supply with automatic voltage selection and battery charging, ensuring reliable operation even during power outages.

  • Programmable Logic and Detection Inputs

  • Includes monitored inputs for abort, manual release, and mode select functions, enabling custom configuration to meet site-specific safety requirements.

  • User-Friendly Operation and Monitoring

  • Equipped with an intuitive LCD display, countdown timers, and easy-to-use front-panel controls for releasing, reset, and silence functions.

  • UL-Listed and NFPA Compliant

  • Designed to comply with UL 864 10th Edition and NFPA releasing standards, ensuring safe and certified performance in suppression applications.

SPECIFICATIONS

  • Model: XT+1R

  • Type: Multi-Area Addressable Releasing Control Unit

  • Power Supply: 5.25A @ 24V DC integrated power supply

  • Input Voltage: 120/240 VAC, 50/60 Hz (auto-select)

  • Releasing Circuits: 2 monitored outputs

  • Notification Circuits: 3-stage NAC outputs

  • Compatible Agents: CO₂, FM-200®, NOVEC™ 1230, Foam, Water Mist

  • Display: LCD with countdown timer and event logs

  • Compliance: UL 864 10th Edition, NFPA 12, 2001

  • Enclosure Color: Red (steel cabinet, lockable)

  HOCHIKI FDAS ATJ-EA - FIXED TEMP/RATE OF RISE HEAT SENSOR  

FEATURES

  • Reliable heat detection for challenging environments

  • The ATJ-EA is ideal for areas where smoke detection may be problematic (dusty, smoky, kitchen, utility) because it senses fixed temperature threshold or a rapid rise in temperature rather than smoke.

  • Digital communication and fast interrupt response

  • Utilises Hochiki’s DCP (Digital Communication Protocol) for noise-immune digital signalling and fast interrupt detection when conditions exceed thresholds.

  • Adjustable detection thresholds and rate-of-rise capability

  • Thresholds adjustable by panel: fixed temp 135 °F–190 °F (~57 °C–90 °C); rate-of-rise approx. 15 °F/min (~8.3 °C/min).

  • Low-profile design with security features

  • Only 2″ high including base, uses twist-lock base compatible with other Hochiki detection heads, and includes optional locking to prevent unauthorized removal.

  • Extended loop capacity and interchangeability

  • Up to 127 devices per SLC loop; shares the same base as other compatible sensors (e.g., smoke or multi-criteria detectors) enabling flexible system design.

SPECIFICATIONS

  • Product Code: 0200‑06148

  • Rate-of-Rise: 15 °F/min; Fixed Temp adjustable 135–190 °F

  • Max Spacing: Up to 70 ft between detectors

  • Power: ~350 µA standby, ~500 µA alarm

  • Temperature Range: 14–122 °F (–10 °C to 50 °C)

  • Mounting: Compatible with standard Hochiki bases (YBN/HSB)

  • Addressing: Up to 127 devices per SLC loop via DCP

  • Listings: UL 864 listed; UL 521 compliant rate-of-rise panel input

  HOCHIKI FDAS SOE-24V CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR  

FEATURES

  • Optimized Fire Detection

  • Reduces false alarms while enhancing response to real fires.

  • High Signal-to-Noise Ratio

  • Maintains sensitivity stability across various environmental conditions.

  • Wide Viewing Angle Alarm Indicator

  • Ensures clear visibility of alarm status from multiple angles.

  • Automatic Drift Compensation

  • Includes maintenance indication to ensure optimal performance.

  • Built-In Magnetic Test Feature

  • Facilitates easy testing and maintenance without removing the detector.

  • Break-Away, Hidden Locking Feature

  • Compatible with Hochiki NS bases for secure installation.

SPECIFICATIONS

  • Smoke Density Range: 1.82–3.16%/ft in open area

  • Operating Temperature Range: 32°F to 120°F (0°C to 49°C)

  • Storage Temperature Range: -22°F to +140°F (-30°C to +60°C)

  • Operating Humidity Limit: <95% RH at 104°F (40°C); <80% RH at 120°F (49°C)

  • Supply Voltage Range: 8–35 VDC; absolute maximum 42 VDC

  • Current Consumption: Standby 59 µA; Minimum Alarm 6 mA; Maximum Alarm 150 mA; Startup 160 µA

  • Startup Time: 25 seconds maximum

  • Reset Time: 100 ms minimum

  • Dimensions: 3.94" diameter × 1.77" height

  • Weight: Approximately 3.4 oz (96.4 g)

Inquire Now

a man riding a skateboard down the side of a ramp
a man riding a skateboard down the side of a ramp
Address

23 1st Ave. Brgy. Bagong Lipunan ng Crame, Cubao, Quezon City, 1111 Metro Manila, Philippines

Contacts

+632 8287 4114 | +632 8254 1594 +632 7720 1310 | + 632 8726 9129
inquiry@fastlink.ph | helpdesk@fastlink.ph

About Us

Our Solutions

Our Services

Contact Us