  HONEYWELL FDAS ES-200X FIRE ALARM CONTROL PANEL WITH COMMUNICATOR  

FEATURES

  • Integrated Dual-Path Communicator

  • Built-in IPOTS‑COM module provides both POTS and IP pathways for central station and remote monitoring.

  • Single Signaling Line Circuit (SLC) Supporting 198 Devices

  • Supports up to 99 detectors and 99 modules on one SLC loop for compact installations.

  • Offline and Local Programming via FS‑Tools

  • Programming via USB or Ethernet using FS‑Tools, enabling upload/download of programming, event logs, and system data.

  • Four NAC Circuits with Flexible Synchronization

  • Each NAC is programmable as Class A or B and supports temporal, continuous, and synchronized output.

  • Comprehensive Alarm and Maintenance Features

  • Includes alarm‑verification logic, pre‑signal options, sequenced evacuation (PAS), sensitivity monitoring, and one‑person walk test.

SPECIFICATIONS

  • Addressable Points Supported: Up to 198 devices (99 detectors + 99 modules) on one SLC

  • Communications: Built-in POTS/IP communicator, optional cellular path

  • NAC Outputs: 4 independent circuits (Class A/B), total max 2.7 A (2.5 A per NAC)

  • Relays: 2 programmable Form‑C plus one fixed trouble relay

  • Display Interface: Integral LCD (approx. 80‑character) with status LEDs

  • Programming Ports: USB and Ethernet, FS‑Tools compatible

  • History Capacity: Up to 1,000 stored events

  • Power Supply: Internal transformer and regulated power supply

  • Listings: UL 864 9/10th Edition listed; NFPA 72 compliant

  HONEYWELL FDAS NFS2-640E  

FEATURES

  • Modular Addressable System Optimized for Mid‑Size Installations

  • Supports up to ten SLC loops and scalable between small standalone or networked systems.

  • ONYX Intelligent Sensing & FlashScan Protocol

  • Nine sensitivity levels with drift compensation, auto detector testing, and ultra-fast response (<2 s polling, <5 s output activation).

  • Large User-Friendly Display & Onboard Programming

  • Features a 640‑character backlit LCD and remote programming via USB or VeriFire Tools.

  • Audio & Mass Notification Integration

  • Optional voice, fire fighter telephone, and analog or digital audio compatible with ONYXWorks systems.

  • High‑Efficiency Power Supply & Battery Monitoring

  • Built-in 3.0 A PSU (6.0 A in alarm), automatic battery monitoring, and onboard charger for large battery banks.

SPECIFICATIONS

  • Signaling Line Circuits (SLCs): 1 standard, expandable to 2 isolated loops (FlashScan or CLIP)

  • Device Capacity: Up to 318 devices per loop, with networked support up to 3,180 devices

  • Power Supply:

  • 120 VAC model: 3.0 A (6.0 A in alarm)

  • 240 VAC model (‑E): 1.5 A (3.0 A in alarm)

  • Notification Appliance Circuits (NACs): Four Class A/B outputs, synchronized and programmable (max 1.5 A each)

  • Protocols Supported: FlashScan, CLIP; NICET/NFPA compliant

  • Listing & Approvals: UL 864, UL 2572 Mass Notification, ULC, CSFM, MEA, ADA compliant

  HONEYWELL FDAS MS-4 FIRE ALARM CONTROL PANELS  

FEATURES

  • Four-Zone Input with Programmable Flexibility

  • Provides four initiating zones—one can be configured for supervisory/waterflow monitoring.

  • Dual NACs with Sync Protocols and Selective Silence

  • Two synchronized NAC circuits support System Sensor, Wheelock, or Gentex appliances with horn mute/strobe continue capability.

  • Expandable to Class A Circuits with Accessory Module

  • Optional converter module provides Class A configuration for initiating and NAC circuits for fault-tolerant installations.

  • i3 Smoke Detector Support for Maintenance Alerts

  • Compatible with System Sensor i3 device features including cleanliness and freeze status feedback.

  • Walk Test Mode Included

  • Silent or audible walk-test options and automatic return to normal operation after one hour.

SPECIFICATIONS

  • Zones Supported: 4 conventional zones, Zone 4 programmable for fire/supervisory/waterflow

  • NAC Outputs: 2 synchronized NACs, selective silence feature supported

  • Power Supply: 3.0 A total output at 24 VDC (expandable to 6.0 A with optional transformer)

  • Detector Compatibility: System Sensor i3 series and standard conventional initiating devices

  • Optional Features: Compatible with Class A converter (CAC‑5X), remote annunciator module (4XLMF), relay module (4XZMF)

  • User Controls: Front panel LEDs, LED indicators per zone, zone/test/reset buttons

  • Listings: UL, FM approved; supports NFPA 72 conventional system role

Inquire Now

a man riding a skateboard down the side of a ramp
a man riding a skateboard down the side of a ramp
Address

23 1st Ave. Brgy. Bagong Lipunan ng Crame, Cubao, Quezon City, 1111 Metro Manila, Philippines

Contacts

+632 8287 4114 | +632 8254 1594 +632 7720 1310 | + 632 8726 9129
inquiry@fastlink.ph | helpdesk@fastlink.ph

About Us

Our Solutions

Our Services

Contact Us