Honeywell- ES-200X Fire Alarm Control Panel with Communicator
HONEYWELL FDAS ES-200X FIRE ALARM CONTROL PANEL WITH COMMUNICATOR
FEATURES
Integrated Dual-Path Communicator
Built-in IPOTS‑COM module provides both POTS and IP pathways for central station and remote monitoring.
Single Signaling Line Circuit (SLC) Supporting 198 Devices
Supports up to 99 detectors and 99 modules on one SLC loop for compact installations.
Offline and Local Programming via FS‑Tools
Programming via USB or Ethernet using FS‑Tools, enabling upload/download of programming, event logs, and system data.
Four NAC Circuits with Flexible Synchronization
Each NAC is programmable as Class A or B and supports temporal, continuous, and synchronized output.
Comprehensive Alarm and Maintenance Features
Includes alarm‑verification logic, pre‑signal options, sequenced evacuation (PAS), sensitivity monitoring, and one‑person walk test.
SPECIFICATIONS
Addressable Points Supported: Up to 198 devices (99 detectors + 99 modules) on one SLC
Communications: Built-in POTS/IP communicator, optional cellular path
NAC Outputs: 4 independent circuits (Class A/B), total max 2.7 A (2.5 A per NAC)
Relays: 2 programmable Form‑C plus one fixed trouble relay
Display Interface: Integral LCD (approx. 80‑character) with status LEDs
Programming Ports: USB and Ethernet, FS‑Tools compatible
History Capacity: Up to 1,000 stored events
Power Supply: Internal transformer and regulated power supply
Listings: UL 864 9/10th Edition listed; NFPA 72 compliant
HONEYWELL FDAS NFS2-640E
FEATURES
Modular Addressable System Optimized for Mid‑Size Installations
Supports up to ten SLC loops and scalable between small standalone or networked systems.
ONYX Intelligent Sensing & FlashScan Protocol
Nine sensitivity levels with drift compensation, auto detector testing, and ultra-fast response (<2 s polling, <5 s output activation).
Large User-Friendly Display & Onboard Programming
Features a 640‑character backlit LCD and remote programming via USB or VeriFire Tools.
Audio & Mass Notification Integration
Optional voice, fire fighter telephone, and analog or digital audio compatible with ONYXWorks systems.
High‑Efficiency Power Supply & Battery Monitoring
Built-in 3.0 A PSU (6.0 A in alarm), automatic battery monitoring, and onboard charger for large battery banks.
SPECIFICATIONS
Signaling Line Circuits (SLCs): 1 standard, expandable to 2 isolated loops (FlashScan or CLIP)
Device Capacity: Up to 318 devices per loop, with networked support up to 3,180 devices
Power Supply:
120 VAC model: 3.0 A (6.0 A in alarm)
240 VAC model (‑E): 1.5 A (3.0 A in alarm)
Notification Appliance Circuits (NACs): Four Class A/B outputs, synchronized and programmable (max 1.5 A each)
Protocols Supported: FlashScan, CLIP; NICET/NFPA compliant
Listing & Approvals: UL 864, UL 2572 Mass Notification, ULC, CSFM, MEA, ADA compliant
HONEYWELL FDAS MS-4 FIRE ALARM CONTROL PANELS
FEATURES
Four-Zone Input with Programmable Flexibility
Provides four initiating zones—one can be configured for supervisory/waterflow monitoring.
Dual NACs with Sync Protocols and Selective Silence
Two synchronized NAC circuits support System Sensor, Wheelock, or Gentex appliances with horn mute/strobe continue capability.
Expandable to Class A Circuits with Accessory Module
Optional converter module provides Class A configuration for initiating and NAC circuits for fault-tolerant installations.
i3 Smoke Detector Support for Maintenance Alerts
Compatible with System Sensor i3 device features including cleanliness and freeze status feedback.
Walk Test Mode Included
Silent or audible walk-test options and automatic return to normal operation after one hour.
SPECIFICATIONS
Zones Supported: 4 conventional zones, Zone 4 programmable for fire/supervisory/waterflow
NAC Outputs: 2 synchronized NACs, selective silence feature supported
Power Supply: 3.0 A total output at 24 VDC (expandable to 6.0 A with optional transformer)
Detector Compatibility: System Sensor i3 series and standard conventional initiating devices
Optional Features: Compatible with Class A converter (CAC‑5X), remote annunciator module (4XLMF), relay module (4XZMF)
User Controls: Front panel LEDs, LED indicators per zone, zone/test/reset buttons
Listings: UL, FM approved; supports NFPA 72 conventional system role
Inquire Now