HONEYWELL FDAS FSP-851 PHOTOELECTRIC SMOKE DETECTORS
FEATURES
Advanced Optical Sensing Technology
Utilizes a state-of-the-art photoelectric sensor that quickly detects smoldering fires with high accuracy.
Addressable Detector
Part of the intelligent series — each detector has a unique address, improving system pinpointing and reducing downtime.
Low-Profile Design
Compact housing ensures minimal visual impact and suits modern building aesthetics.
Drift Compensation
Automatically adjusts sensitivity for dust accumulation over time to reduce false alarms.
360° Visible LED Indicator
Provides visual indication of device status from any direction — alarm, trouble, or normal.
SPECIFICATIONS
Detector Type: Intelligent photoelectric smoke detector
Compatibility: Compatible with Notifier Onyx and CLIP protocol panels
Operating Voltage: 15 to 32 VDC
Standby Current: 300 µA (average)
Sensitivity: 1.0 to 2.5% per foot obscuration
Operating Temperature: 32°F to 100°F (0°C to 38°C)
Humidity Range: 10% to 93% RH non-condensing
Diameter: 6.1 inches (155 mm)
Height: 2.0 inches (51 mm) installed in B710LP base
Approvals: UL, FM, MEA, CSFM
HONEYWELL FDAS DNR PHOTOELECTRIC DUCT SMOKE DETECTOR
FEATURES
Reliable Air Duct Smoke Detection
Designed for early detection of smoke in air handling systems to prevent the circulation of smoke throughout a building.
Photoelectric Sensing Technology
Employs advanced photoelectric sensing to provide accurate detection of visible smoke particles with minimal false alarms.
Rugged and Versatile Design
Housed in a durable, gray plastic enclosure with clear cover for easy viewing of status indicators and maintenance.
Simplified Installation and Maintenance
Includes a plug-in sensor head and a large terminal strip for easy wiring and servicing.
Comprehensive Compatibility
Compatible with a wide range of conventional and addressable fire alarm control panels.
SPECIFICATIONS
Air Velocity Range: 100 – 4,000 ft/min (0.5 – 20.32 m/s)
Operating Temperature Range: –4 °F to 158 °F (–20 °C to 70 °C)
Storage Temperature Range: –22 °F to 158 °F (–30 °C to 70 °C)
Operating Humidity Range: 0 % – 95 % RH (non-condensing)
Rectangular Housing Dimensions: 14.38″ L × 5″ W × 2.5″ D (37 cm × 12.7 cm × 6.35 cm)
Square Housing Dimensions: 7.75″ L × 9″ W × 2.5″ D (19.7 cm × 22.9 cm × 6.35 cm)
Weight: 1.6 lb (0.73 kg)
Listings/Approvals: UL 268A; FM; CSFM; UL S911 (check current status)
Conduit Knock-out: ¾″ for mounting and wiring access
HONEYWELL FDAS FS20X FLAME DETECTOR
FEATURES
Multi-Spectrum Detection
Utilizes a combination of UV, dual IR, and visible light sensors for enhanced flame detection.
Wide Detection Range
Detects a 1 sq. ft. heptane fire at distances greater than 200 feet.
Advanced Signal Processing
Employs Electronic Frequency Analysis for improved false alarm immunity and reliable detection.
Environmental Immunity
Operates effectively in harsh environments, including areas with arc welding activity.
Versatile Mounting Options
Suitable for various industrial applications with flexible installation configurations.
SPECIFICATIONS
Operating Voltage: 24 VDC nominal (18–32 VDC)
Sensitivity Settings: Very high, high, medium, low (switch selectable)
Field of View: 90° full core of vision, ±45° from on-axis
Loop Resistance: 50 to 400 Ohms
Conduit Entries: Two 1/2" NPT
Operating Temperature Range: -40°C to +75°C (-40°F to +167°F)
Humidity Range: 0 to 95% RH (non-condensing)
Ingress Protection: IP66
Certifications: FM, CSA, ATEX, IECEx
Inquire Now