Honeywell- HAQ61 Series IAQ Sensors
HONEYWELL BUILDING MANAGEMENT SYSTEM HAQ61 SERIES IAQ SENSORS
FEATURES
Multi-Parameter Measurement
Simultaneously monitors five air quality parameters — temperature, humidity, CO₂, PM2.5, and formaldehyde (HCHO) — and estimates TVOC based on HCHO.
Built-in Modbus Communication
Uses RS-485 Modbus RTU to interface with building automation systems and upload real-time air quality data.
Optional Screen Display
Available in versions with or without a TFT display. The screen version shows six parameters on a split screen and indicates air quality levels visually (e.g. face icons) based on PM2.5.
SPECIFICATIONS
Power Supply: 110–240 VAC, 50/60 Hz
Operating Temperature Range: –10 °C to +55 °C
Humidity Measurement Range / Accuracy: 0–99% RH, ±5% RH
CO₂ Range: 400–2000 ppm, accuracy ±(50 ppm + 5%)
PM2.5 Range / Accuracy: 0–999 µg/m³; 0–100 µg/m³: ±15 µg/m³; above 100 µg/m³: ±15%
Formaldehyde (HCHO) & TVOC Range: 0–999 ppb; 0–100 ppb: ±20 ppb; 100–999 ppb: ±20% of measured value
Communication Protocol: Modbus RTU, RS-485
HONEYWELL BUILDING MANAGEMENT SYSTEM T755 TEMPERATURE SENSOR
FEATURES
General-use electronic temperature sensor for HVAC and industrial applications
The T755 series is designed to be simple to use and broadly featured, suitable for monitoring return air, discharge air, or mixed air temperatures.
High accuracy & quick response
The sensors are rated at 1,097 Ω PTC at 77 °F (25 °C) and described as “fast response time and highly accurate.
SPECIFICATIONS
Sensor Type: PTC thermistor, 1,097 Ω at 77 °F (25 °C)
Probe: ½″ (6.35 mm) stainless steel with epoxy fill
Mounting: Compatible with T775—indoor, outdoor (weatherproof), water resistant or water tight variants
Accuracy: High precision; fast response time
Operating Range: (For WR/WT models) –40 to 270 °F (–40 to 132 °C)
Certifications: RoHS compliant
HONEYWELL BUILDING MANAGEMENT SYSTEM H7012 ROOM HUMIDITY SENSOR
FEATURES
Capacitance-type Humidity Sensing Element
Provides accurate relative humidity measurement via a wall-mounted capacitance sensor, making it suitable for HVAC room-control, indication, and alarm-monitoring applications.
Plug-in Two-Piece Design
Includes a wiring sub-base that can be installed and wired separately from the front electronics module, simplifying installation and maintenance.
Wide Sensing Range
Relative humidity range of 5 %RH to 95 %RH typical and ambient operating temperatures from 0 °C to +50 °C for normal use.
SPECIFICATIONS
Humidity Sensing Range: 5…95 %RH
Humidity Accuracy (at 25 °C / 24 Vac): ±3 %RH in the 30…70 %RH range; ±5 %RH in 10…30 %RH and 70…90 %RH; ±10 %RH in 5…10 %RH and 90…95 %RH.
Output Signal – Humidity: 0…10 Vdc ≈ 0…100 %RH (for standard models)
Temperature Sensing Element (for H7012B): Pt 1000 or NTC 20 kΩ or 0…10 V output
Operating Temperature Range: 0 °C to +50 °C (32 °F to 122 °F)
Storage/Transport Temperature: -25 °C to +70 °C (-13 °F to +158 °F)
Maximum Wiring Distance (Sensor to Controller): Up to 200 m (≈660 ft) using shielded wiring per installation instructions