Honeywell- ML8824A Series Electric Linear Valve Actuator
HONEYWELL BUILDING MANAGEMENT SYSTEM ML8824A SERIES ELECTRIC LINEAR VALVE ACTUATOR
FEATURES
Quick Installation with Self-Adaptation and Speed Control
Designed for fast setup without calibration; includes a self-adapting mode and adjustable travel speed for optimized control.
Low Power, Maintenance-Free Operation
Consumes minimal energy and requires little to no ongoing maintenance.
Manual Override and Direction Flexibility
Manual operation is provided with override capability. Inputs include voltage or current, while DIP switches enable selectable travel direction.
SPECIFICATIONS
Ambient Operating Range: –10 °C to +55 °C (5–95% RH); Storage (medium temperature): –40 °C to +65 °C
Media Temperature Handling: Up to 130 °C
Input Signals: 0–10 Vdc, 2–10 Vdc (impedance >100 kΩ); 0–20 mA, 4–20 mA (impedance <0.125 kΩ)
Feedback: Same voltage/current signal options
Power Requirements: 24 Vac ±15%, 50/60 Hz or 24 Vdc (+15%/–10%); Power consumption: 7 VA or 14.5 VA depending on model
Travel & Force: Stroke length of 20 mm or 40 mm; Closing force of ≥600 N to ≥1800 N depending on model
Protection & Construction: Electrical protection class III, IP54 rating; materials: PC upper cover, plastics or cast aluminum housing, cast aluminum bracket
HONEYWELL BUILDING MANAGEMENT SYSTEM GREEN CLASS METERS
FEATURES
Cost‑effective energy benchmarking
The Green Class line is designed to provide a lower‑cost solution to monitor energy usage trends and estimate CO₂ emissions, helping facilities manage sustainability metrics.
Sub‑metering focused
These meters allow tracking of individual loads, departments or sub‑panels for cost allocation and energy management rather than full high‑accuracy revenue metering.
Suits building energy management systems (BEMS)
They integrate into building automation and provide interval data capable of supporting benchmarking, demand analysis and energy‑saving strategies.
SPECIFICATIONS
Sensor Availability: Split-core sensors standard; optional solid-core (100 & 200 A)
Enclosure Types: Green JIC steel (indoor); optional gray NEMA 4X (indoor/outdoor); MMU configuration possible
Accuracy: ANSI C12.20, ±0.2% (1%–100% load)
Memory: Non-volatile (retains data during power loss)
Pulse Output: Fixed-value dry contact
Sensor Distance: Supports up to 2,000 ft remote sensor placement
Model Configurations: Available in multiple amp ratings (100 A – 3,200 A) and voltage systems (e.g., 120/208 V, 277/480 V, 347/600 V)
HONEYWELL BUILDING MANAGEMENT SYSTEM SMART METERS
FEATURES
Advanced communications
Smart Meters provide two‑way communication capabilities (e.g., via RS‑485, Ethernet or mesh networks) enabling remote reading, diagnostics and integration into AMI/EMS systems.
Real‑time consumption insights
These meters allow users (and facility managers) to view near‑real‑time data on power usage, enabling better decision‑making on energy consumption and cost.
Support for renewable/interactive energy systems
Smart meters help monitor bi‑directional flows (in case of solar/EV export) and support grid‑modernisation efforts.
SPECIFICATIONS
Sensor Options: Split-core standard; solid-core optional (100 & 200 A)
Remote Sensor Distance: Up to 500 ft
Data Logging: Stores interval kW/kVAR data for 72 days (FIFO)
External Channels: Two optional channels for third-party meter inputs (gas, water, BTU, etc.)
Enclosures: Green JIC steel (standard), Gray NEMA 4X (indoor/outdoor optional)
Accuracy & Standards: ANSI C12.20, CE Mark, UL/CUL
Communications: RS-485, Ethernet, optional phone modem; multiple protocol compatibility
Networking: Up to 52 devices, daisy-chain or star config, up to 4,000 ft cable run
Inquire Now
Address
23 1st Ave. Brgy. Bagong Lipunan ng Crame, Cubao, Quezon City, 1111 Metro Manila, Philippines
Contacts
+632 8287 4114 | +632 8254 1594 +632 7720 1310 | + 632 8726 9129
inquiry@fastlink.ph | helpdesk@fastlink.ph
About Us
Our Solutions
Our Services
Contact Us