Honeywell- NFS2-640E (Intelligent Addressable Fire Alarm Control Panel)

  HONEYWELL FIRE DETECTION & ALARM SYSTEM NFS2-640E  

FEATURES

  • Highly scalable for large installations

  • Supports up to 4 SLC loops, 318 devices per loop, and up to 159 outputs; suitable for campuses, high-rises, and industrial complexes.

  • Advanced detection algorithms

  • FlashScan® protocol enables fast polling (<2 s) and multi-detector decision-making and includes self-optimization, drift compensation, alarm verification, and pre-alarm logic.

SPECIFICATIONS

  • SLC Capacity: 1–2 loops, up to 159 detectors + 159 modules per loop

  • Primary Power Input: 220/240 VAC, 50/60 Hz, 2.5 A (for “E” version)

  • Current Draw (Standby/Alarm): 0.250 A + 0.035 A per NAC; panel backlight ≈ 0.100 A

  • Total 24 V Output: 6.0 A in alarm (shared)

  • Notification Circuits (NACs): Four Class A/B NACs, each 1.5 A

  • Auxiliary Power: 1.25 A resettable 24 V; two non-resettable 24 V outputs; 5 V @ 0.15 A

  • Battery Charging Range: 18 Ah – 200 Ah

  • Float Voltage Rate: 27.6 V

  • Operating Temperature: 0 °C to +49 °C, 93% RH non‑condensing

  • Certifications / Listings: UL 864 (10th edition), UL 2572 (mass notification), ULC-S527, IBC (seismic) compliance

  HONEYWELL FIRE DETECTION & ALARM SYSTEM FSP-951 SERIES INTELLIGENT ‑IN PHOTOELECTRIC SMOKE DETECTORS  

FEATURES

  • Advanced Photoelectric Detection

  • Uses a specialized sensing chamber to provide reliable smoke detection for early fire warning.

  • Addressable System Integration

  • Fully compatible with intelligent fire alarm control panels for precise location identification.

  • Drift Compensation

  • Adjusts sensitivity over time to reduce false alarms caused by dust accumulation.

SPECIFICATIONS

  • Model: FSP-951 Series

  • Type: Intelligent addressable photoelectric smoke detector

  • Detection Method: Light-scattering photoelectric sensor

  • Mounting: Plug-in base compatible

  • Features: Drift compensation, LED status indicators

  • Application: Commercial, institutional, and residential facilities

  HONEYWELL FIRE DETECTION & ALARM SYSTEM FCO-951 SERIES ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR  

FEATURES

  • Dual Detection Technology

  • Combines fire detection with carbon monoxide sensing in a single device.

  • Multi-Criteria Sensing

  • Uses multiple sensors (smoke, heat, gas) to improve accuracy and reduce nuisance alarms.

  • Addressable Communication

  • Reports both fire and CO events to the fire alarm control panel with specific location data.

  • Life Safety Enhancement

  • Detects both flaming/smoldering fires and dangerous CO gas exposure.

SPECIFICATIONS

  • Model: FCO-951 Series

  • Type: Advanced multi-criteria fire/CO detector

  • Detection Method: Smoke, heat, and carbon monoxide sensors

  • Mounting: Plug-in base compatible

  • Communication: Intelligent addressable protocol

  • Application: Buildings requiring combined fire and CO protection

Inquire Now

a man riding a skateboard down the side of a ramp
a man riding a skateboard down the side of a ramp
Address

23 1st Ave. Brgy. Bagong Lipunan ng Crame, Cubao, Quezon City, 1111 Metro Manila, Philippines

Contacts

+632 8287 4114 | +632 8254 1594 +632 7720 1310 | + 632 8726 9129
inquiry@fastlink.ph | helpdesk@fastlink.ph

About Us

Our Solutions

Our Services

Contact Us